Circulating load calculator

Estimate the circulating load of a closed grinding circuit from samples of the cyclone feed, underflow and overflow. Use the % solids of each, or the % passing one sieve size in each, or both as a cross-check.

Results

The example values are filled in so you can see how it works. Results update as you type.

The formula

CL=UO=Do−DfDf−DuCL=o−ff−u

where

U, O
dry solids in the cyclone underflow and overflow (t/h)
Df, Du, Do
dilution ratio (water ÷ solids by mass) of the feed, underflow and overflow
f, u, o
% passing one chosen sieve size in the feed, underflow and overflow

Want the background? Read Mass balance data reconciliation for mineral processing plants: weighted least squares and the chi-square test.

Discuss your plant with a metallurgist

Tiegel is a Perth metallurgy company. We help with testwork, plant optimisation, metal accounting and investigations.

Talk to a metallurgist

These calculators use standard published formulas and are provided as a guide. Check results before relying on them for design or reporting.