Tiegel home Talk to a metallurgist

Flotation gas dispersion calculator (Jg, Sb, carrying rate)

Enter the air flow to the cell, the cell cross-sectional area and the Sauter mean bubble size. Add the concentrate solids and froth area for the carrying rate.

Results

The example values are filled in so you can see how it works. Results update as you type.

The formula

Jg=QgASb=6Jgd32k=P×Sb×Rf

where

Jg
superficial gas velocity: air flow per unit cross-sectional area of the cell (m/s, often quoted in cm/s)
Qg, A
air flow rate (m³/s) and cell cross-sectional area (m²)
Sb
bubble surface area flux: bubble surface passing through each square metre of the cell every second (s⁻¹)
d32
Sauter mean bubble diameter (m)
k
flotation rate constant (min⁻¹ or s⁻¹)
P
floatability of the mineral, which reagents control
Rf
froth recovery: the fraction of attached particles that survive the froth and report to concentrate

Want the background? Read Flotation reagents and froth: collectors, frothers, modifiers and gas dispersion.

Discuss your plant with a metallurgist

Tiegel is a Perth metallurgy company. We help with testwork, plant optimisation, metal accounting and investigations.

Talk to a metallurgist

These calculators use standard published formulas and are provided as a guide. Check results before relying on them for design or reporting.