Agitator power and tip speed calculator
Enter the impeller power number from the supplier, its speed and diameter, the slurry density, the tank volume and the drive efficiency.
The example values are filled in so you can see how it works. Results update as you type.
The formula
where
- power drawn by the impeller (W)
- impeller power number, from the impeller supplier for the actual design; fully turbulent flow
- slurry density (kg/m³)
- impeller speed (revolutions per second)
- impeller diameter (m)
Want the background? Read Agitator design for leach and CIL tanks: power number, tip speed and solids suspension.
Discuss your plant with a metallurgist
Tiegel is a Perth metallurgy company. We help with testwork, plant optimisation, metal accounting and investigations.
Talk to a metallurgistThese calculators use standard published formulas and are provided as a guide. Check results before relying on them for design or reporting.