Dissolved oxygen saturation calculator

Calculate how much oxygen water can hold when saturated with air, at your plant's temperature, air pressure and salinity. It is the ceiling for dissolved oxygen from air sparging.

Results

The example values are filled in so you can see how it works. Results update as you type.

The formula

lnC*=−139.34411+1.575701×10⁵T−6.642308×10⁷T2+1.243800×10¹⁰T3−8.621949×10¹¹T4

where

C*
oxygen solubility in air-saturated fresh water at 1 atm (mg/L)
T
water temperature (K) = °C + 273.15