Reagent dosing calculator (g/t to pump flow)
Enter the dose, the dry tonnage and the solution strength. For % w/w strengths, also enter the solution density.
The example values are filled in so you can see how it works. Results update as you type.
The formula
where
- dosing pump flow (mL/min)
- reagent addition per tonne of dry ore (g/t)
- dry ore feed rate (t/h)
- reagent strength in grams of active reagent per millilitre of solution (10% w/v = 0.10 g/mL)
Want the background? Read Reagent dosing calculations: g/t, solution strength and pump flow.
Discuss your plant with a metallurgist
Tiegel is a Perth metallurgy company. We help with testwork, plant optimisation, metal accounting and investigations.
Talk to a metallurgistThese calculators use standard published formulas and are provided as a guide. Check results before relying on them for design or reporting.