Tiegel home Talk to a metallurgist

Operating work index calculator

The operating work index uses the plant's own power, throughput and sizes in Bond's equation. Comparing it with the laboratory work index shows how efficiently a grinding circuit is using its energy.

Results

The example values are filled in so you can see how it works. Results update as you type.

The formula

W=PQWio=W(10P80−10F80)

where

P
mill power drawn (kW)
Q
dry solids throughput (t/h)
W
specific energy actually used (kWh/t)
Wio
operating work index (kWh/t)
P80, F80
80% passing sizes of the circuit product and feed (µm)

Want the background? Read Rapid work index estimates from plant samples: separating ore hardness from grinding circuit performance.

Discuss your plant with a metallurgist

Tiegel is a Perth metallurgy company. We help with testwork, plant optimisation, metal accounting and investigations.

Talk to a metallurgist

These calculators use standard published formulas and are provided as a guide. Check results before relying on them for design or reporting.