Tiegel home Talk to a metallurgist

Leach tank and flotation residence time calculator

Calculate the slurry volume flow from the solids tonnage and % solids, then the residence time in a train of leach tanks or flotation cells, or the total volume needed for a target time.

Results

The example values are filled in so you can see how it works. Results update as you type.

The formula

Qslurry=Qs×(1SGs+1−CwCw)τ=n·Vt·(1−εair)Qslurry

where

Qs
dry solids feed rate (t/h)
Qslurry
slurry volume flow (m³/h)
n, Vt
number of tanks or cells, and live volume of each (m³)
εair
fraction of volume taken by air (flotation cells; 0 for leach tanks)
τ
residence time (h)

Want the background? Read CIL and CIP gold circuits: choosing between them and tracing gold losses.

Discuss your plant with a metallurgist

Tiegel is a Perth metallurgy company. We help with testwork, plant optimisation, metal accounting and investigations.

Talk to a metallurgist

These calculators use standard published formulas and are provided as a guide. Check results before relying on them for design or reporting.