Leach tank and flotation residence time calculator
Calculate the slurry volume flow from the solids tonnage and % solids, then the residence time in a train of leach tanks or flotation cells, or the total volume needed for a target time.
The example values are filled in so you can see how it works. Results update as you type.
The formula
where
- dry solids feed rate (t/h)
- slurry volume flow (m³/h)
- ,
- number of tanks or cells, and live volume of each (m³)
- fraction of volume taken by air (flotation cells; 0 for leach tanks)
- residence time (h)
Want the background? Read CIL and CIP gold circuits: choosing between them and tracing gold losses.
Discuss your plant with a metallurgist
Tiegel is a Perth metallurgy company. We help with testwork, plant optimisation, metal accounting and investigations.
Talk to a metallurgistThese calculators use standard published formulas and are provided as a guide. Check results before relying on them for design or reporting.