PI controller lambda tuning calculator

Enter the step test result: the output step and the PV change, both in % of range, the dead time and the time constant. Choose lambda, or leave it at 0 for three times the larger of dead time and time constant.

Results

The example values are filled in so you can see how it works. Results update as you type.

The formula

Kc=τKp(λ+θ)Ti=τ

where

λ
chosen closed-loop time constant: how fast the loop should respond; a common, robust starting point is three times the larger of θ and τ

Want the background? Read Process control for metallurgists: PID loops, step tests and lambda tuning.