A leach tank must keep a large volume of slurry suspended and mixed for a day or more. Insufficient agitation allows coarse particles to settle, so the tank sands up and gold leaves unleached. Excessive agitation wastes power and, in a CIL tank, breaks activated carbon into fines that carry gold out of the circuit. The agitator consists of a motor and gearbox mounted on the tank, driving a shaft with one or more impellers, and baffles on the tank wall prevent the slurry from rotating as a body so that the impeller's energy goes into mixing.
This article covers the principal agitator calculations and the checks most relevant to leach and CIL tanks. The agitator power calculator performs the power and tip speed calculations.
Impeller power
where
- power drawn by the impeller (W)
- impeller power number, from the impeller supplier for the actual design; fully turbulent flow
- slurry density (kg/m³)
- impeller speed (revolutions per second)
- impeller diameter (m)
The power number depends on the impeller design. It is roughly 5 for a flat-blade (Rushton) turbine and well below 1 for modern hydrofoils, which is one reason hydrofoils are common in large leach tanks. The supplier's value for the actual impeller should be used.
Worked example: a 4.0 m hydrofoil with a power number of 0.3 rotates at 30 rpm (0.5 rev/s) in slurry of 1.4 t/m³. Power = 0.3 × 1,400 × 0.5³ × 4.0⁵ = 53,760 W, or 54 kW, and the tip speed is π × 4.0 × 0.5 = 6.3 m/s. In a 2,000 m³ tank, this is 0.027 kW/m³, and with a drive efficiency of 90% the motor draws about 60 kW.
where
- impeller Reynolds number; above about 10,000 the power number is constant
- shaft torque (N·m), which sizes the gearbox and shaft
- slurry viscosity (Pa·s)
The shaft torque in the example is 53,760 ÷ (2π × 0.5) = 17.1 kN·m, which determines the gearbox and shaft size. Even at a slurry viscosity of 10 mPa·s, the impeller Reynolds number is 1,400 × 0.5 × 4² ÷ 0.01 = 1.1 million, well into the turbulent range, so a constant power number applies.
Solids suspension
where
- just-suspended speed: the slowest impeller speed at which no particle rests on the tank floor for more than a moment (rev/s)
- a constant for the impeller type and tank geometry, from published charts or testwork
- kinematic viscosity of the liquid (m²/s)
- solid density minus liquid density (kg/m³); liquid density
- solids loading: mass of solids per 100 mass units of liquid
- particle size (m), often the coarse end of the distribution
The just-suspended speed increases with particle size and density difference and decreases strongly with impeller diameter. The constant S depends on the impeller type and its clearance above the tank floor and is obtained from published correlations or testwork, so a calculated value should be treated as a guide and confirmed with the supplier. In practice, leach tanks are designed to keep the coarsest particles in motion, with a margin for coarse surges from the grinding circuit and for build-up on the tank floor.
A slowly rising power draw at constant speed, or a falling live volume, suggests that solids are accumulating on the floor. A tank that stops while full of slurry may not restart once the solids settle, so designs allow for restart torque or include a means of fluidising the bed. Agitation also disperses air or oxygen into the slurry, as discussed in dissolved oxygen in gold leaching.
Carbon attrition in CIL and CIP tanks
Activated carbon is softer than ore and breaks under impact from impeller blades or in high-shear pumps, and carbon fines carry loaded gold out of the circuit. Low tip speeds, hydrofoil impellers and recessed-impeller carbon transfer pumps are common measures to limit attrition; see carbon regeneration and carbon losses.
Glossary
- Impeller
- The rotating blades on an agitator shaft that move the slurry.
- Power number
- A dimensionless number for an impeller that links power to speed, diameter and density in turbulent flow.
- Tip speed
- The speed of the impeller blade tips: π × diameter × revolutions per second.
- Baffles
- Vertical strips on the tank wall that stop the slurry swirling as a whole.
- Hydrofoil
- An impeller with shaped blades that pumps slurry efficiently with a low power number.
- Just-suspended speed
- The slowest speed at which no particle rests on the tank floor for more than a moment.
- Sanding
- Build-up of settled coarse solids on a tank floor.
- Attrition
- Wear and breakage of carbon granules into fines.
Frequently asked questions
How is agitator power calculated?
Power = power number × slurry density × speed³ × impeller diameter⁵, with speed in revolutions per second. For a 4 m hydrofoil with a power number of 0.3 at 30 rpm in slurry of 1.4 t/m³, the result is about 54 kW.
Why are hydrofoil impellers used in leach tanks?
They move a large volume of slurry for little power and at low shear, which suits large tanks and reduces carbon breakage in CIL.
What is the just-suspended speed?
The lowest impeller speed that keeps all particles off the tank floor. It is obtained from the Zwietering correlation or from testwork and depends on particle size, density, solids loading and impeller design.
Why does a tank sand up?
Coarse or dense solids arrive faster than the agitator can keep them suspended, often after a change in grind, a coarse surge or a reduction in agitator speed.
Discuss your plant with a metallurgist
Tiegel is a Perth metallurgy company. We help with testwork, plant optimisation, metal accounting and investigations, and we build the Tiegel Suite software.
Talk to a metallurgistReferences and further reading
- Zwietering, T.N. (1958). Suspending of solid particles in liquid by agitators. Chemical Engineering Science, 8, 244–253.
- Paul, E.L., Atiemo-Obeng, V.A. and Kresta, S.M. (eds) (2004). Handbook of Industrial Mixing: Science and Practice. Wiley.
- Marsden, J.O. and House, C.I. (2006). The Chemistry of Gold Extraction, 2nd edition. Society for Mining, Metallurgy and Exploration.
Worked examples and charts marked illustrative use invented figures, not data from any operation.