A gold leach plant measures cyanide several times a shift. Too little slows gold dissolution, while too much wastes reagent and increases the cyanide load in the tailings. The usual method is titration with silver nitrate from a burette until an indicator shows that all the free cyanide has reacted. It is one of the most frequent measurements in a gold plant and one of the easiest to get slightly wrong. This article covers the procedure, the chemistry, the calculation and the common sources of error, together with the companion titration for lime.
Chemistry of the titration
Silver ions react with free cyanide to form the dicyanoargentate complex:
Ag⁺ + 2 CN⁻ → Ag(CN)₂⁻
Two cyanide ions are consumed for each silver ion. While free cyanide remains, added silver is taken up as the colourless complex. Once all the free cyanide has reacted, further silver reacts with the indicator. With rhodanine, the solution changes from yellow to salmon pink. With potassium iodide, silver iodide forms and the solution becomes faintly and permanently cloudy (opalescent).
Procedure
- Take the sample and filter it immediately. Solids continue to consume cyanide, and suspended particles obscure the end point.
- Pipette a fixed volume of filtrate, for example 10 mL, into a clean flask, diluting with a little deionised water if needed to make the colour change visible.
- Add the indicator: a few drops of rhodanine solution, or a small amount of potassium iodide solution.
- Titrate from a burette with standardised silver nitrate solution, swirling constantly and adding drop by drop near the end point.
- Read the burette at the end point and calculate the result.
- For quality control, titrate a standard cyanide solution each shift and check the silver nitrate strength against a primary standard regularly. Store silver nitrate in a dark bottle, because light decomposes it.
Calculation
where
- volume of silver nitrate used to reach the end point (mL)
- molarity of the silver nitrate solution (mol/L)
- two cyanide ions react with each silver ion
- molar mass of sodium cyanide (g/mol); use 26.02 to report as free CN⁻
- volume of the filtered sample titrated (mL)
Worked example: a 10 mL sample requires 5.2 mL of 0.0100 M silver nitrate to reach the end point.
NaCN = 5.2 × 0.0100 × 2 × 49.01 × 1000 ÷ 10 = 510 mg/L, or 0.51 g/L.
Expressed as free cyanide ion (CN⁻) rather than NaCN, the same titre gives 5.2 × 0.0100 × 2 × 26.02 × 1000 ÷ 10 = 271 mg/L. The basis should always be stated, because mixing the two is a common source of confusion between the laboratory and the plant.
Many plants make up their silver nitrate so that a convenient factor applies, for example so that each millilitre corresponds to a round number of milligrams per litre of NaCN for their standard sample volume. A factor of this kind is acceptable provided it is recalculated whenever the silver nitrate strength or the sample volume changes.
Interferences
The titration measures free cyanide plus cyanide that is weakly held in some metal complexes. In clean solutions the result is close to the true free cyanide. Where copper, zinc or nickel are present, part of the cyanide held by those metals can react with silver during the titration, so the result reads higher than the true free cyanide, and the two indicators are affected differently. Sites with significant copper in solution often confirm free cyanide by another method, such as an ion-selective electrode or an online analyser calibrated against it.
Sulphide ions in solution also react with silver and cause errors. They can be removed by treatment with lead carbonate before titration.
For compliance reporting of cyanide in tailings and discharge water, laboratories use defined methods for weak acid dissociable (WAD) and total cyanide rather than this process titration.
Protective alkalinity
Leach solutions are kept alkaline so that cyanide remains as cyanide ion and is not lost as hydrogen cyanide gas. Plants control this through pH and through measurement of protective alkalinity, the lime available to neutralise acid. It is determined by titration with a standard acid, commonly oxalic or hydrochloric acid, to the phenolphthalein end point (pink to colourless):
where
- volume of standard acid to the end point (mL)
- normality of the acid (equivalents per litre)
- equivalent mass of CaO (g per equivalent: 56.08 ÷ 2)
- sample volume (mL)
Worked example: a 25 mL sample requires 3.1 mL of 0.020 N acid. CaO = 3.1 × 0.020 × 28.04 × 1000 ÷ 25 = 70 mg/L CaO.
The cyanide and lime titrations can be carried out in sequence on the same sample, following the site's validated procedure.
Safety
Cyanide solutions must never be acidified outside a fume cupboard, because acid releases hydrogen cyanide gas, and acids should be kept separate from cyanide samples. Gloves and eye protection are required, since silver nitrate stains skin and is corrosive. Sample disposal and spill response should follow the site cyanide management plan.
Glossary
- Titration
- Adding a reagent of known strength from a burette until a colour change shows the reaction is complete.
- Titre
- The volume of reagent used to reach the end point.
- End point
- The colour change that shows all the cyanide (or alkali) has reacted.
- Rhodanine
- An indicator that turns from yellow to salmon pink when excess silver is present.
- Free cyanide
- Cyanide present as cyanide ion or hydrogen cyanide, not bound in metal complexes.
- WAD cyanide
- Weak acid dissociable cyanide: free cyanide plus cyanide in weak and moderately strong metal complexes.
- Molarity
- Concentration in moles per litre.
- Protective alkalinity
- Lime available in solution to keep the pH high, reported as mg/L CaO.
Frequently asked questions
How is a silver nitrate titre converted to mg/L NaCN?
Multiply the titre in mL by the silver nitrate molarity, by 2, by 49.01 and by 1000, then divide by the sample volume in mL. With 0.01 M silver nitrate and a 10 mL sample, each mL of titre corresponds to 98 mg/L NaCN.
Should rhodanine or potassium iodide be used?
Both are in common use. Rhodanine gives a colour change that some operators find easier to see, while potassium iodide gives a cloudiness. They respond differently to copper and other metals, so one should be chosen, validated for the site's solution chemistry and used consistently.
Why does the titration read higher than the analyser?
In solutions containing copper or zinc, the silver nitrate titration includes some cyanide from metal complexes, so it can read higher than the true free cyanide. Check the indicator, the silver nitrate strength and the solution chemistry.
What is the difference between NaCN and CN⁻ results?
The same titre gives a NaCN figure 49.01 ÷ 26.02 = 1.88 times the CN⁻ figure. The basis should always be stated.
Discuss your plant with a metallurgist
Tiegel is a Perth metallurgy company. We help with testwork, plant optimisation, metal accounting and investigations, and we build the Tiegel Suite software.
Talk to a metallurgistReferences and further reading
- APHA, AWWA and WEF. Standard Methods for the Examination of Water and Wastewater. Method 4500-CN⁻ D, Titrimetric method.
- Marsden, J.O. and House, C.I. (2006). The Chemistry of Gold Extraction, 2nd edition. Society for Mining, Metallurgy and Exploration.
- International Cyanide Management Institute. International Cyanide Management Code for the Manufacture, Transport and Use of Cyanide in the Production of Gold. Link